Application
The cables are designed for use as subscriber distribution cables and as connection between central offices in local access networks. The cables are jelly filled and suitable for installation in ducts. The cables are also available for direct burial in the ground and aerial installation with integral suspension strand. An armoured option is offered for direct burial installations. A figure-8 self support option is offered for aerial installation.
Standards
• CW 1326 (For unscreened cable)
• CW 1179 (For screened cable)
• CW 1252 (For self-supporting cable)
Construction
Conductors
Solid annealed bare copper, 0.5mm as per class 1 of BS 6360/IEC 60228
Isolation
Solid polyethylene as per BS EN 50290-2-23/BS 6234/IEC 60708
Twisted Pairs
Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk
Elément de câblage
Twisted Pairs
Core Assemblée
Cables are composed of 10-pair units
Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors
Moisture Barrier (optional)
A layer of aluminium tape (0.15mm) coated with PE-copolymer on one or both sides is applied longitudinally with overlap over the cable core to provide shielding coverage and ensure a barrier against water vapor
Filling
The cable core interstices are filled with petroleum jelly to avoid longitudinal water penetration within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and shield, shield and sheath within the cable core
Gaine
Black low density polyethylene as per BS 6234/IEC 60708, being able to withstand exposure to sunlight, temperature variations, ground chemicals and other environmental contaminants
Ripcord
Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal
Paires de rechange(optional)
Spare pairs may be incorporated for 200 and larger pair cables
Fil de continuité(optional)
Tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen
Electrical Properties
*For screened cables of 20 pairs or less, the maximum average mutual capacitance shall not apply and the maximum for 99% of cases shall be increased by 3nF
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 10 x Overall Diameter (unarmoured cables);15 x Overall Diameter (armoured cables)
Colour Code
Standard colour code is per CW 1326 given in the following Colour Code Chart
Cabling Element No. |
a-wire |
b-wire |
Cabling Element No. |
a-wire |
b-wire |
1 |
WHITE |
BLUE |
6 |
RED |
BLUE |
2 |
WHITE |
ORANGE |
7 |
RED |
ORANGE |
3 |
WHITE |
GREEN |
8 |
RED |
GREEN |
4 |
WHITE |
BROWN |
9 |
RED |
BROWN |
5 |
WHITE |
GREY |
10 |
RED |
GREY |
Units binders
No. of Units |
Binder Colour |
No. of Units |
Binder Colour |
1 |
BLUE |
6 |
WHITE |
2 |
ORANGE |
7 |
RED |
3 |
GREEN |
8 |
BLACK |
4 |
BROWN |
9 |
YELLOW |
5 |
GREY |
10 |
VIOLET |
Dimensions And Weight
Solid PE Insulated and Unscreened/Screened PE Sheathed Jelly Filled Cable to CW 1326, CW 1326/1179
Cable Code |
Nombre de paires |
Gaine Epaisseur minimum mm |
Diamètre maximum
mm
(Unscreened) |
Poids nominal kg/km
(Unscreened) |
Diamètre maximum mm (Screened) |
Poids nominal kg/km (Screened) |
0.5mm Conductor, 1.05mm Insulated Wire |
TP1326-2YF(L)2Y-2P05 |
2 |
1.1 |
8.5 |
55 |
10.0 |
65 |
TP1326-2YF(L)2Y-5P05 |
5 |
1.2 |
8.5 |
77 |
10.0 |
87 |
TP1326-2YF(L)2Y-10P05 |
10 |
1.2 |
12.0 |
126 |
13.5 |
137 |
TP1326-2YF(L)2Y-20P05 |
20 |
1.3 |
15.0 |
221 |
16.5 |
231 |
TP1326-2YF(L)2Y-30P05 |
30 |
1.4 |
18.0 |
332 |
19.5 |
347 |
TP1326-2YF(L)2Y-50P05 |
50 |
1.4 |
19.5 |
483 |
21.0 |
504 |
TP1326-2YF(L)2Y-100P05 |
100 |
1.5 |
25.0 |
933 |
26.5 |
956 |
*The above part number will be changed for unscreened cables by deleting the (L).
Solid PE Insulated, PE Inner Sheathed, Steel Wire Armoured and PE Outer Sheathed Jelly Filled Cable to CW 1326/1198 (Unscreened)
Cable Code |
Nombre de paires |
Bedding Epaisseur minimum
mm |
Fil d'acier de diamètre
mm |
Gaine Epaisseur minimum
mm |
Diamètre maximum
mm |
Poids nominal
kg/km |
0.5mm Conductor, 1.05mm Insulated Wire |
TP1326-2YF2Y(SWA)2Y-2P05 |
2 |
1.1 |
0.9 |
0.9 |
13.7 |
241 |
TP1326-2YF2Y(SWA)2Y-5P05 |
5 |
1.2 |
0.9 |
0.9 |
13.7 |
274 |
TP1326-2YF2Y(SWA)2Y-10P05 |
10 |
1.2 |
0.9 |
0.9 |
17.2 |
351 |
TP1326-2YF2Y(SWA)2Y-20P05 |
20 |
1.3 |
1.25 |
0.9 |
20.9 |
499 |
TP1326-2YF2Y(SWA)2Y-30P05 |
30 |
1.4 |
2.0 |
1.0 |
24.8 |
749 |
TP1326-2YF2Y(SWA)2Y-50P05 |
50 |
1.4 |
2.0 |
1.0 |
26.3 |
1123 |
TP1326-2YF2Y(SWA)2Y-100P05 |
100 |
1.5 |
2.0 |
1.1 |
32.0 |
1763 |
Solid PE Insulated, PE Inner Sheathed, Steel Wire Armoured and PE Outer Sheathed Jelly Filled Cable to CW 1326
/1179/1198 (Screened)
Cable Code |
Nombre de paires |
Bedding Epaisseur minimum
mm |
Fil d'acier de diamètre
mm |
Gaine Epaisseur minimum
mm |
Diamètre maximum
mm |
Poids nominal
kg/km |
0.5mm Conductor, 1.05mm Insulated Wire |
TP1326-2YF(L)2Y(SWA)2Y-2P05 |
2 |
1.1 |
0.9 |
0.9 |
15.2 |
251 |
TP1326-2YF(L)2Y(SWA)2Y-5P05 |
5 |
1.2 |
0.9 |
0.9 |
15.2 |
286 |
TP1326-2YF(L)2Y(SWA)2Y-10P05 |
10 |
1.2 |
1.25 |
0.9 |
19.4 |
363 |
TP1326-2YF(L)2Y(SWA)2Y-20P05 |
20 |
1.3 |
2.0 |
1.0 |
23.3 |
501 |
TP1326-2YF(L)2Y(SWA)2Y-30P05 |
30 |
1.4 |
2.0 |
1.0 |
26.3 |
752 |
TP1326-2YF(L)2Y(SWA)2Y-50P05 |
50 |
1.4 |
2.0 |
1.1 |
28.0 |
1139 |
TP1326-2YF(L)2Y(SWA)2Y-100P05 |
100 |
1.5 |
2.0 |
1.2 |
30.5 |
1786 |